| POINTER PULSE DD3710 |
| HAND HELD PULSED LASER AND PULSED TENS |
| - |
Laser
and Transmittance Electrical Nerve Stimulation (TENS) devices are used
for the symptomatic relief of chronic (long term) intractable pain and
as an adjunctive treatment in the management of post surgical traumatic
pain problems. |
| - |
Laser
is also used as a substitution of invasive acupuncture treatment. Laser
acupuncture means directly irradiating some key body points on the
surface of the skin. |
|
|
|
| - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
| • |
A combination of output of laser as well as electrical stimulation. |
| • |
An accurate point locator |
| • |
Incorporates an effective push button stimulation feature + Laser stimulation. |
| • |
Use for the immediate treatment of the point or area following its detection. |
|
|
|
| - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
| POINTER PULSE DD3710 FEATURES: |
| • |
Modern Spring Type Probe Tip |
| • |
Sensitivity Adjustment |
| • |
Immediate Point Location and Treatment |
| • |
T.E.N.S. Stimulation PLUS Laser stimulation continuous |
| • |
10 Hz pulsed laser stimulation |
|
|
| - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
| YOUR WHOLE KIT INCLUDES : |
|
| 1. |
Point Pulse Unit |
| 2. |
Hard Carrying Case |
| 3. |
9V Alkaline Battery |
| 4. |
Screw Drive |
| 5. |
Grounding Pole |
| 6. |
User Manual |
|
|
| - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
| ADVANTAGES OF LASER STIMULATION: |
| • |
Painless and without sensation of numbness |
| • |
Harmless, no tissue damage. |
| • |
Complete sterility. |
|
| - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
| HOW TO USE POINTER PULSE DD3170: |
| 1. |
Insert
the 9 V battery into the alkaline battery compartment, the positive and
negative poles of the battery should always be matched correctly with
the respective battery contacts. A 9 V Duracell or other alkaline
battery is recommended for the best performance |
| 2. |
For sef use, touch the grounding metal plate on the unit and then search for the point. |
| 3. |
Press
each point slightly, the probe uses a spring mechanism so that a
constant pressure maybe maintained during location. The respective
trigger point is located when a continuous sound is heard from the
buzzer and at the same time the green LED light located on the top of
the unit is flashing continuously. |
| 4. |
The sound emitted from the buzzer during point detection can be adjusted by turning the audio control trimmer of the unit. |
|
|
| 5. |
If
stimulation is required on this point, simply adjust the intensity knob
"INT" to an acceptable level and press the ADP/STI button. When this
button is released, the unit is immediately returned to the point
detection mode. Pressing the APD/STI button again will produce output
stimulation. |
| 6. |
It
is recommended to begin treatment with low intensity setting,
thereafter turning the "INT" control until a comfortable intensity is
reached. |
| 7. |
If laser stimulation is required, switch on the Laser output to either"I"(continuous output) or "II" position. |
| 8. |
Turn off the laser by switch it to "0" position after laser stimulation is completed. |
| 9. |
In
order to treat patients, the grounding pole must be attached with the
plug jack at the end of unit. The patient must hold the grounding pole
to complete the electrical circuit which then activates the detection
and stimulation functions. The above procedures 3-9 are then followed. |
| 10. |
Turn off the unit after use. Remove the battery from the unit when the device will not be used for a long period. |
|
|
| - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - |
| POINTER PULSE DD3170 TECHNICAL SPECIFICATION |
| For Electric Stimulation |
| Output Current |
2-45 mA r.m.s. |
| Pulse Rate |
10 Hz (Fixed) ∮20% |
| Pulse Width |
260 S (Fixed) ∮20% |
|
| |
| For Laser Stimulation |
| Laser Wavelength |
650nm |
| Maximum Power Output |
<5mW, solid state diode |
| " I " |
Continuous Laser Output |
| " II " |
10 Hz Pulsed Laser Output |
|
| |
| Power Source |
9V Alkaline Battery |
| Unit Dimensions |
210 x 85(mm)/8.4" x 3.4" |
| Unit Weight |
100 gm (unit only) |
| Package Info |
260 x 95 x 45(mm) /10.4" x 3.8" x 1.8"