Multiple Electronic Acupunctoscope with Therapeutic Switch |
The WQ-6F(57-6F) Electronic Acupunctoscope is an advanced apparatus specially designed and modified on the basis of Model 57 - 6D and WQ - 10C . It is based on recent results of theoretical research work and clinical practices in acupuncture therapy and anesthesia. It is the newest product of the 2nd-generation line of Transistor Electronic Acupunctoscopes in China at present, and has the following features: |
 |
|
| |
| WQ-6F Feature: |
- Multi-purpose: The apparatus can be used in acupuncture therapy, acupuncture anesthesia, needleless therapy, measurement of the sensitivity of meridian and for physiological experiments etc.
- Multiple transmit messages :
The apparatus transmits eight different waveforms of impulse series. Their frequencies vary from 0 - 20c/s, 0 - 200c/s with continuous adjustment and multiple possible combinations.
The apparatus consists of two independent sections (A and B) with seven channels. It is possible to select two different frequencies (A and B) and output waveforms simultaneously.
- High amplitude of output, divided into "High" and "Low" ranges, smooth adjustment, high stability and low power consumption, non-interference between channels, parallel or serial connection of output terminals to enhance stimulation for various purpose.
|
|
CON: continuous (disperse & dense)
D - D: dense - disperse
N - S: normal saw tooth
RDE - FDI: rise dense - fall disperse
INT: intermittent
R -F: rise - fall (undulatory)
I -S: inverse saw tooth
RDI -FDE: rise disperse - fall dense |
|
| |
| WQ-6F Operation: |
- The adjustment of stimulating waveforms and frequencies. Amplitude: There are two types, as selected: constant amplitude (CA) or amplitude modulation (AM) switch.
Frequencies: They are controlled by the knobs and switches, as
follows:
f1: fixed frequencies
f2: variable frequencies
m: multiplier
Output frequency F = mf
The alternative frequencies of a variable waveform including two frequencies are controlled by Alternative Frequency (F at) knob.
For beginners, plug the monitoring loudspeaker into the output socket and practice the above procedure and familiarize yourself with different combinations of output waveforms and frequencies. The monitoring loudspeaker can also use to check the output sockets and leads.
- Acupuncture therapy and anesthesia
(1) Set "Amplitude" knobs to zero and all output controlled switches to separate positions (as 1, 2) . Set "Hi - Lo" switch to "Hi" or "Lo" position as required. Amplitude of "Lo" position is 1/3 of "Hi".
(2) Plug output leads into sockets (1 - 7) , fasten their clips to the handles of the needles.
(3) Set the desirable waveform and frequencies (f1 , f2 , m, CA, AM) .
(4)Turn "ON" main switch.
(5) Adjust amplitude to appropriate degree.
(6) Select parallel (1//2, 3//4) or series (5 + 6 + 7) connection as required, while amplitude is regulated by these knobs simultaneously.
- Needleless therapy
(1) Use needleless therapy electrode. Fill the cup of electrode with absorbent cotton soaked with salt solution. Attach the electrode onto the acupuncture point. Set "Hi - Lo" switch to "Hi" position.
(2) In case of weak stimulation follow the same steps described in 2, outputs taken from sockets 1-7
(3) For strong stimulation, the output will be taken from the socket marked " ? " , Set output controlled switch of 5 , 6 , 7 channels to 5 + 6 + 7 position and the amplitude is regulated by 5 , 6 , 7 channels simultaneously.
|
| |
|
A: Section A
B: Section B
F1: Fixed frequencies
F2: Variable frequencies
m: Multiplier
Hi: High amplitude
Lo: Low amplitude
CA: Constant amplitude
AM: Amplitude modulation
1,2;3,4;5,6,7: Channels work separately
1//2;3//4: parallel connection
5+6+7: series connection
Fat: alternative frequencies of variable waveform |
|
| |
Notes: The WQ-6F can emit 2 waveforms simultaneously, 1 from section A and 1 from section B.
7 channels do not interfere each other, but you can connect outputs in parallel or in succession to enhance stimulation for various purposes. When channels are connected in parallel, the output current is enhanced while the output voltage maintains the same. When channels are connected in succession, the output voltage is enhanced while the output current maintains the same. |
| |
 |
 |
Accessories
Output leads with electrodes 1 set
Output leads with clips 7sets
Monitoring loudspeaker 1 pc
1 artificial leather carrying case
1 instruction manual |
|
| |
| Electronic Acupunctoscope Technical Description |
| Model name |
WQ-6F |
|
| Power source |
DC , 4.5 volts insert three No 1 batteries (Size "D") |
|
| Output |
Section A: 1, 2 , 3 , 4 channels. Both 1, 2 and 3 , 4 can be connected in parallel into one channel. |
|
Section B : 5 , 6, 7 channels. These three channels can be connected in series into one channel as a needleless therapy output. |
| Waveforms type series |
There are 8 patterns: continuous, intermittent, dense - disperse, rise - fall (undulatory), normal saw tooth, inverse saw tooth, rise dense - fall disperse, fall dense - rise disperse (refer to table 1) . The alternating frequency of every variable wave form varies from 14 -25c/min with continuous adjustment. |
| Amplitude of impulse |
The electric resistance of the human body under needling is about 250 Ohm - the peak current of the impulse is not lower than 40mA(10V) |
|
| Waveform type |
Asymmetrical bipolar impulse |
| Frequencies and width of impulse |
| Section |
A |
B |
| Multiplier M |
x 10 |
x 1 |
x 10 |
| Frequency F (c/s) |
0 - 200 |
0 - 20 |
0 - 200 |
| Width T (μs) |
400 - 600 |
600 - 800 |
200 - 300 |
|
|
| Digital Display |
No |
|
| Dimensions |
23.5 x 17 x 7.5 cm (9.4" x 6.8" x 3 ") |
|
|
|
 |
| Shipping Weight: 2.40 kg |
 |
| Shipping Dimension: 32.80 X 22.00 X 13.00 cm |
 |
Ground Shipping Cost: $23.95 USD
Above shipping charge is for USA & Canada only. The international shipping price will be subject to the destination. |
 |
| This product was added to our catalog on Saturday 12 November, 2005. |
| |
|
|
|
 |
 |
|